ProStart CT-3271 Guía de instalación Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 27
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
CT-3271 p.23
Remote function
The remote’s function can be configured as follow:
Mode2/ Function6/ Option 1
Mode2/ Function6/ Option 2
Button
is for the LOCK/ UNLOCK
functions
Button is for the START/ STOP
functions
Buttons
&
(together) is for
the TRUNK release function.
Button is for the STOP functions
(by default).
Button is for the START functions
(by default).
Buttons
&
(together) is for
the TRUNK release function.
Diagnostics via parking lights
Diagnostic table for shutdown.
Parking lights flashes
Cause
1
Runtime has expired.
2
Shutdown by remote.
Ready mode is activated.
3
Failed start.
4
Brake shutdown.
10
Hood shutdown.
Flash for 30sec
Panic mode
Flash for 60sec
Alarm triggered
Diagnostic table for start failure.
Parking lights flashes
Cause
1
(Manual transmission only)
Ready mode is not activated.
Tach signal is not learned.
1 slow 2 quick
The system is set to valet mode.
3
(Automatic transmission
only)
The parking brake is active.
Yellow loop is connected.
4
Brake wire is active
6
A tach signal is detected before Ignition.
10
Hood wire is active.
Note: The installer can also use the PRG-1000 to diagnose shutdown and remote start failures.